What was found
PIT - FOUND FLOOR SUPPORT BEAM CORRODED 160 INCHES, STATION 500D TO STATION 380 FLOOR SUPPORT BEAM 26L. CORROSION LEVEL 1, TASK C53-208-01. REMOVED CORROSION, REPAIRED SUPPORT BEAM, REPLACED SECTION PER TYPICAL REPAIR 53-20-04. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FLOOR SUPPORT BEAM CORRODED 160 INCHES, STATION 500D TO STATION 380 FLOOR SUPPORT BEAM 26L. CORROSION LEVEL 1, TASK C53-208-01. REMOVED CORROSION, REPAIRED SUPPORT BEAM, REPLACED SECTION PER TYPICAL REPAIR 53-20-04. (M)