What was found
PIT - FOUND CORROSION .035 INCH DEEP, INTERCOSTAL CAP STRAP DOUBLER STATION 787-847 STRINGER 25-26R. CORROSION LEVEL 1, TASK NR C53-202-01. REPLACED STRAP PER SRM 51-40-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND CORROSION .035 INCH DEEP, INTERCOSTAL CAP STRAP DOUBLER STATION 787-847 STRINGER 25-26R. CORROSION LEVEL 1, TASK NR C53-202-01. REPLACED STRAP PER SRM 51-40-02. (M)