What was found
CLT - FOUND ANGLE DENTED .75 INCH BY .75 INCH, BS 639, LBL 68 AT CREASE BEAM WEB. FABRICATED AND INSTALLED NEW ANGLE PER BOEING DRAWING 69-37422, SRM 51-30-01, 51-40-00 AND 51-40-03. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND ANGLE DENTED .75 INCH BY .75 INCH, BS 639, LBL 68 AT CREASE BEAM WEB. FABRICATED AND INSTALLED NEW ANGLE PER BOEING DRAWING 69-37422, SRM 51-30-01, 51-40-00 AND 51-40-03. (M)