What was found
CLT - FOUND GUSSET/FITTING CRACKED .5 INCH, HORIZONTAL STABILIZER CENTER SECTION, AFT LEFT INT SECTION OF BEAMS. FABRICATED NEW ANGLE PER BOEING DRAWING 65-47598, INSTALLED PER SRM 51-40-02 AND 03. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND GUSSET/FITTING CRACKED .5 INCH, HORIZONTAL STABILIZER CENTER SECTION, AFT LEFT INT SECTION OF BEAMS. FABRICATED NEW ANGLE PER BOEING DRAWING 65-47598, INSTALLED PER SRM 51-40-02 AND 03. (M)