What was found
CLT - FOUND FLOORBEAM CORRODED 2 INCHES BY 3 INCHES, BS 1006, LBL 10. DAMAGE REMOVED, INSTALLED FILLER AND REPAIR ANGLES PER SRM 53-10-9 FIG 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOORBEAM CORRODED 2 INCHES BY 3 INCHES, BS 1006, LBL 10. DAMAGE REMOVED, INSTALLED FILLER AND REPAIR ANGLES PER SRM 53-10-9 FIG 2. (M)