What was found
CLT - FOUND FLOORBEAM T-CAP CORRODED 1 INCH BY .5 INCH AREA, BS 312, BL 0. DAMAGE REMOVED, SPLICED IN REPAIR ANGLES AND T-CAP SECTION PER TYPICAL REPAIR 53-10-13. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOORBEAM T-CAP CORRODED 1 INCH BY .5 INCH AREA, BS 312, BL 0. DAMAGE REMOVED, SPLICED IN REPAIR ANGLES AND T-CAP SECTION PER TYPICAL REPAIR 53-10-13. (M)