What was found
SJO - FOUND 3 INCH SQUARE CORROSION, BS 986 TO 1006 BETWEEN STRINGER 26L AND 27L. FABIRCATED AND INSTALLED REPAIR CHANNEL PER SRM 51-10-3. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SJO - FOUND 3 INCH SQUARE CORROSION, BS 986 TO 1006 BETWEEN STRINGER 26L AND 27L. FABIRCATED AND INSTALLED REPAIR CHANNEL PER SRM 51-10-3. (M)