What was found
PIT - FOUND RUDDER DELAMINATED AND GOUGED IN SEVERAL AREAS, LT AND RT RUDDER SKIN AND ONE LEADING EDGE GOUGE. COMPOSITE WET LAYUP REPAIR 230. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND RUDDER DELAMINATED AND GOUGED IN SEVERAL AREAS, LT AND RT RUDDER SKIN AND ONE LEADING EDGE GOUGE. COMPOSITE WET LAYUP REPAIR 230. (M)