What was found
PIT - FOUND RIGHT AILERON CRACKED .5 INCH BY .5 INCH, AILERON FRONT SPAR UPPER FLANGE AT NR 1 HINGE ACCESS. INSTALLED WET LAYUP WITH A 230 CURE WITH ONE EXTRA PLY PER SRM 51-70-17, EA 70844. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND RIGHT AILERON CRACKED .5 INCH BY .5 INCH, AILERON FRONT SPAR UPPER FLANGE AT NR 1 HINGE ACCESS. INSTALLED WET LAYUP WITH A 230 CURE WITH ONE EXTRA PLY PER SRM 51-70-17, EA 70844. (M)