What was found
PIT - FOUND UPPER CHORD CORRODED 1 INCH BY 4 INCHES, BS 986.5. CORROSION LEVEL NR 1, TASK NR C53-107-02. CLEAN/TREAT/PRIME, ALSO CUT OUT DAMAGE SPLICE IN NEW STRUCTURE PER TYP REPAIR 53-60-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND UPPER CHORD CORRODED 1 INCH BY 4 INCHES, BS 986.5. CORROSION LEVEL NR 1, TASK NR C53-107-02. CLEAN/TREAT/PRIME, ALSO CUT OUT DAMAGE SPLICE IN NEW STRUCTURE PER TYP REPAIR 53-60-01. (M)