What was found
PIT - FOUND UPPER CHORD CORRODED 1 INCH BY 3 INCHES CORROSION, BS 967. CORROSION LEVEL 1, TASK NR C53-107-02. CLEAN/TREAT/PRIME AND INSTALL STRAP PER EA 70646 IAW SRM 53-00-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND UPPER CHORD CORRODED 1 INCH BY 3 INCHES CORROSION, BS 967. CORROSION LEVEL 1, TASK NR C53-107-02. CLEAN/TREAT/PRIME AND INSTALL STRAP PER EA 70646 IAW SRM 53-00-51. (M)