What was found
CLT - FOUND U-CHANNEL CORRODED 20 INCHES BY 2 INCH AREA, BS 560-580, BETWEEN STRINGERS 27R AND 28R. FABRICATED AND INSTALLED NEW U-CHANNEL PER SRM 53-30-04 AND 51-10-02. (M)