What was found
PIT - FOUND FRAME CRACKED .5 INCH, BS 500C AT STRINGER 8R. ROUTED OUT DAMAGE, INSTALLED FILLER AND DOUBLER PER TYPICAL REPAIR 53-10-14 AND EA 70647. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FRAME CRACKED .5 INCH, BS 500C AT STRINGER 8R. ROUTED OUT DAMAGE, INSTALLED FILLER AND DOUBLER PER TYPICAL REPAIR 53-10-14 AND EA 70647. (M)