What was found
PIT - FOUND SKIN CRACKED 5 INCHES BY 7 INCHES, FRAME STATION 580, S5L. REPAIR PCW, 5 INCHES BY 7 INCH DOUBLER INSTALLED PER SRM 53-00-01 FIG 202. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND SKIN CRACKED 5 INCHES BY 7 INCHES, FRAME STATION 580, S5L. REPAIR PCW, 5 INCHES BY 7 INCH DOUBLER INSTALLED PER SRM 53-00-01 FIG 202. (M)