What was found
PIT - FOUND SKIN CRACKED 8 INCHES BY 6 INCH AREA, BETWEEN FRAME STATION 500C AND 500D, S5L, 6 INCHES AFT 500C. REPAIR PCW, 8 INCHES BY 6 INCH DOUBLER INSTALLED PER SRM 53-00-01 FIG 201. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND SKIN CRACKED 8 INCHES BY 6 INCH AREA, BETWEEN FRAME STATION 500C AND 500D, S5L, 6 INCHES AFT 500C. REPAIR PCW, 8 INCHES BY 6 INCH DOUBLER INSTALLED PER SRM 53-00-01 FIG 201. (M)