What was found
TPA - FOUND STRINGER CORRODED 10 SQUARE INCHES, PREVIOUSLY SPLICED SECTION OF STRINGER 27L AT STATION 967. CORROSION LEVEL 1. SPLICED IN NEW SECTION OF STRINGER USING SPLICES RETAINED FROM PREVIOUS REPAIR PER SRM 53-10-3 FIG 1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TPA - FOUND STRINGER CORRODED 10 SQUARE INCHES, PREVIOUSLY SPLICED SECTION OF STRINGER 27L AT STATION 967. CORROSION LEVEL 1. SPLICED IN NEW SECTION OF STRINGER USING SPLICES RETAINED FROM PREVIOUS REPAIR PER SRM 53-10-3 FIG 1. (M)