What was found
CLT - FOUND FLOORBEAM CORRODED 2 INCH BY 18 INCH AREA, BS 947 LBL 12 TO RBL 6. DAMAGE REMOVED, REPLACED T-CAP PER TYPICAL REPAIR 53-60-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOORBEAM CORRODED 2 INCH BY 18 INCH AREA, BS 947 LBL 12 TO RBL 6. DAMAGE REMOVED, REPLACED T-CAP PER TYPICAL REPAIR 53-60-02. (M)