What was found
CLT - FOUND FRAME CRACKED 3 INCHES, BS 954, BETWEEN STRINGER 9 AND 10R, INNER RADIUS. DAMAGE REMOVED, INSTALLED NEW PARTS PER SRM 51-40-03, 51-40-02 AND BAC DRAWING NR J65-46561. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FRAME CRACKED 3 INCHES, BS 954, BETWEEN STRINGER 9 AND 10R, INNER RADIUS. DAMAGE REMOVED, INSTALLED NEW PARTS PER SRM 51-40-03, 51-40-02 AND BAC DRAWING NR J65-46561. (M)