What was found
CLT - FOUND BEAM CRACKED .5 INCH, BS 707 TO 711, BBL 0, LOWER ROW OF FASTENERS. INSTALLED REPAIR DOUBLER PER EA 69679 AND SB 737-57-1210 FIG 5. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND BEAM CRACKED .5 INCH, BS 707 TO 711, BBL 0, LOWER ROW OF FASTENERS. INSTALLED REPAIR DOUBLER PER EA 69679 AND SB 737-57-1210 FIG 5. (M)