What was found
CLT - FOUND FLOORBEAM WITH ELONGATED CLIPNUT HOLES .125 INCH AND .25 INCH, BS 328, LBL 28. INSTALLED REPAIR ANGLES PER SRM 53-10-51, FIG 206. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOORBEAM WITH ELONGATED CLIPNUT HOLES .125 INCH AND .25 INCH, BS 328, LBL 28. INSTALLED REPAIR ANGLES PER SRM 53-10-51, FIG 206. (M)