What was found
PIT - FOUND STRAP CRACKED TWO PLACES .5 INCH ON BOTH FORWARD SIDES, STATION 312 BOTTOM FLOORBEAM SUPPORT STRAP 10 INCHES LEFT C/L. DEFECTIVE PART REPLACED WITH IDENTICAL PART. REPLACED RIVETS PER SRM 52-40-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND STRAP CRACKED TWO PLACES .5 INCH ON BOTH FORWARD SIDES, STATION 312 BOTTOM FLOORBEAM SUPPORT STRAP 10 INCHES LEFT C/L. DEFECTIVE PART REPLACED WITH IDENTICAL PART. REPLACED RIVETS PER SRM 52-40-02. (M)