What was found
CLT - FOUND CREASEBEAM ANGLE CORRODED 40 INCHES, BS 947.5 AFT SERVICE DOOR FRAME. CORROSION LEVEL 1, TASK NR C53-107-02. REMOVED AND REPLACED Z-ANGLE AND WEB PER SRM 51-10-2, 51-40-2, AND 53-60-15. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND CREASEBEAM ANGLE CORRODED 40 INCHES, BS 947.5 AFT SERVICE DOOR FRAME. CORROSION LEVEL 1, TASK NR C53-107-02. REMOVED AND REPLACED Z-ANGLE AND WEB PER SRM 51-10-2, 51-40-2, AND 53-60-15. (M)