What was found
CLT - FOUND FLOORBEAM CORRODED, ENTIRE LENGTH OF FLOORBEAM, BS 294.5 STRINGER 17L TO 17R. CORROSION LEVEL 1, TASK NR C53-107-02. DAMAGE REMOVED, INSTALLED DOUBLER PER SRM 53-10-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOORBEAM CORRODED, ENTIRE LENGTH OF FLOORBEAM, BS 294.5 STRINGER 17L TO 17R. CORROSION LEVEL 1, TASK NR C53-107-02. DAMAGE REMOVED, INSTALLED DOUBLER PER SRM 53-10-51. (M)