What was found
CLT - FOUND FRAME CORRODED 14 INCH AREA, BS 727B, LEFT AND RIGHT KEEL BEAMS, LOWER FLANGE. REMOVED DAMAGE, INSTALLED NEW FRAME SECTION PER SRM 51-40-02 AND 51-40-05. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FRAME CORRODED 14 INCH AREA, BS 727B, LEFT AND RIGHT KEEL BEAMS, LOWER FLANGE. REMOVED DAMAGE, INSTALLED NEW FRAME SECTION PER SRM 51-40-02 AND 51-40-05. (M)