What was found
CLT - FOUND KEEL BEAM CHORD CORRODED 6 INCHES BY 2 INCHES, BS 500C PLUS 9 TO 500D, RBL 7. DAMAGE REMOVED, INSTALLED REPAIR ANGLES PER SRM 53-30-12 FIG 202, EA 69842. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND KEEL BEAM CHORD CORRODED 6 INCHES BY 2 INCHES, BS 500C PLUS 9 TO 500D, RBL 7. DAMAGE REMOVED, INSTALLED REPAIR ANGLES PER SRM 53-30-12 FIG 202, EA 69842. (M)