What was found
CLT - FOUND ATTACH LUG FITTING CORRODED .75 INCH TOTAL SURFACE AREA, LEFT HORIZONTAL STABILIZER CENTER SECTION, FRONT LOWER FORWARD LUG. CORROSION REMOVED, FABRICATED AND INSTALLED NEW BUSHING PER SRM 55-10-10. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND ATTACH LUG FITTING CORRODED .75 INCH TOTAL SURFACE AREA, LEFT HORIZONTAL STABILIZER CENTER SECTION, FRONT LOWER FORWARD LUG. CORROSION REMOVED, FABRICATED AND INSTALLED NEW BUSHING PER SRM 55-10-10. (M)