What was found
CLT - FOUND FRAME CRACKED .5 INCH, BS 616, RBL 64 INCHES, 8 INCHES BELOW FLOOR. INSTALLED FILLER AND STIFFENER ANGLE PER TR 53-62-01, HT J020-37-22. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FRAME CRACKED .5 INCH, BS 616, RBL 64 INCHES, 8 INCHES BELOW FLOOR. INSTALLED FILLER AND STIFFENER ANGLE PER TR 53-62-01, HT J020-37-22. (M)