What was found
CLT - FOUND FLOORBEAM CORRODED 2 INCHES BY 2 INCHES, BS 294.5 LGL 709. CORROSION LEVEL 1, TASK NR C53-107-01. UPPER T-CHORD REPAIRED PER TR 53-10-04 B. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOORBEAM CORRODED 2 INCHES BY 2 INCHES, BS 294.5 LGL 709. CORROSION LEVEL 1, TASK NR C53-107-01. UPPER T-CHORD REPAIRED PER TR 53-10-04 B. (M)