What was found
CLT - FOUND CREASE BEAM WEB CORRODED 10 SQUARE INCHES, LEFT SIDE BS 927-947. FABRICATED NEW WEB PER DRAWING 65-52878 AND INSTALLED PER SRM 51-30-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND CREASE BEAM WEB CORRODED 10 SQUARE INCHES, LEFT SIDE BS 927-947. FABRICATED NEW WEB PER DRAWING 65-52878 AND INSTALLED PER SRM 51-30-2. (M)