What was found
CLT - FOUND FRAME CORRODED 2 INCHES BY 5 INCHES, BS 500 BL0. CORROSION LEVEL 1, TASK NR 90-25-01. CUT OUT DAMAGE ON FRM, HFEC INSPECTION FMD PARTS, HT TREAT/INSTALLED PER SRM 53-10-4/51-10-6/53-30-1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FRAME CORRODED 2 INCHES BY 5 INCHES, BS 500 BL0. CORROSION LEVEL 1, TASK NR 90-25-01. CUT OUT DAMAGE ON FRM, HFEC INSPECTION FMD PARTS, HT TREAT/INSTALLED PER SRM 53-10-4/51-10-6/53-30-1. (M)