What was found
TPA - FOUND STRINGER CORRODED 6 SQUARE INCH AREA, STRINGER 25L STATION 967 PLUS 10 INCHES. CORROSION LEVEL 2. SPLICED IN SECTION OF STRINGER PER SRM 53-00-03 PAGE 201-204. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TPA - FOUND STRINGER CORRODED 6 SQUARE INCH AREA, STRINGER 25L STATION 967 PLUS 10 INCHES. CORROSION LEVEL 2. SPLICED IN SECTION OF STRINGER PER SRM 53-00-03 PAGE 201-204. (M)