What was found
PIT - FOUND FLOORBOARD ATTACH ANGLE CORRODED IN SEVEN AREAS 1 INCH BY 4 INCHES, STATION 773 FROM 25L-25R. REMOVED CORRODED SECTION AND INSTALLED REPAIR ANGLES IAW TYPICAL REPAIR 53-10-06B. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FLOORBOARD ATTACH ANGLE CORRODED IN SEVEN AREAS 1 INCH BY 4 INCHES, STATION 773 FROM 25L-25R. REMOVED CORRODED SECTION AND INSTALLED REPAIR ANGLES IAW TYPICAL REPAIR 53-10-06B. (M)