PIT - FOUND FLOORBOARD ATTACH ANGLE CORRODED 100 INCHES BY 3 INCHES, STATION 727-727E ABOVE STRINGER 25L. REMOVED CORROSION, TREATED, PRIMED AND PAINTED PER SRM 51-10-02. (M)