What was found
PIT - FOUND FLOORBOARD ATTACH ANGLE CORRODED 71 INCHES BY 2 INCHES, STATION 782-853 ABOVE STRINGER 26R. REMOVED AND REPLACED TIE DOWN RAIL TRACK EXTRUSION REPLACED PER SRM 53-00-53. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FLOORBOARD ATTACH ANGLE CORRODED 71 INCHES BY 2 INCHES, STATION 782-853 ABOVE STRINGER 26R. REMOVED AND REPLACED TIE DOWN RAIL TRACK EXTRUSION REPLACED PER SRM 53-00-53. (M)