What was found
PIT - FOUND FLOORBOARD ATTACH RAIL CORRODED 66 INCHES BY 3 INCH AREA, FS 727E-793 AT STRINGER 25L. REMOVED CORROSION, TREATED, PRIMED, PAINTED PER SRM 51-10-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FLOORBOARD ATTACH RAIL CORRODED 66 INCHES BY 3 INCH AREA, FS 727E-793 AT STRINGER 25L. REMOVED CORROSION, TREATED, PRIMED, PAINTED PER SRM 51-10-02. (M)