What was found
PIT - FOUND FLOORBOARD ATTACH ANGLE CORRODED 1 INCH BY 1 INCH AREA, STA 727E, 3 INCHES LEFT OF C/L. REMOVED CORROSION, TREATED, PRIMED, PAINTED PER SRM 51-10-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FLOORBOARD ATTACH ANGLE CORRODED 1 INCH BY 1 INCH AREA, STA 727E, 3 INCHES LEFT OF C/L. REMOVED CORROSION, TREATED, PRIMED, PAINTED PER SRM 51-10-02. (M)