What was found
PIT - FOUND FLOORBOARD ATTACH ANGLE CORRODED 1 INCH BY 1 INCH AREA, STATION 727B ABOVE STRINGER 27L. CORROSION REMOVED, TREATED, PRIMED, PAINTED PER SRM 51-10-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FLOORBOARD ATTACH ANGLE CORRODED 1 INCH BY 1 INCH AREA, STATION 727B ABOVE STRINGER 27L. CORROSION REMOVED, TREATED, PRIMED, PAINTED PER SRM 51-10-02. (M)