What was found
PIT - FOUND BEAM CRACKED 1 INCH, WEB IN KEEL BEAM 18 INCHES FORWARD STATION 722 UNDER AUX HYDRAULIC PUMP. REPAIR ANGLE PER SRM 51-70-11 FIG 1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND BEAM CRACKED 1 INCH, WEB IN KEEL BEAM 18 INCHES FORWARD STATION 722 UNDER AUX HYDRAULIC PUMP. REPAIR ANGLE PER SRM 51-70-11 FIG 1. (M)