What was found
PIT - FOUND FITTING CRACKED .75 INCH, L ANGLE TOP CENTER FITTING STATION 312 (RS) FORWARD SERVICE DOOR. INSTALLED DOUBLER STRAP PER 51-40-02 AND 51-40-03. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FITTING CRACKED .75 INCH, L ANGLE TOP CENTER FITTING STATION 312 (RS) FORWARD SERVICE DOOR. INSTALLED DOUBLER STRAP PER 51-40-02 AND 51-40-03. (M)