What was found
PIT - FOUND FRAME CRACKED .500 INCH CRACK, FRAME STATION 827 BETWEEN S8 AND S9 AT RIVET ON CLIP. INSTALLED DOUBLER AND FILLER PER TYPICAL REPAIR 53-10-14. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FRAME CRACKED .500 INCH CRACK, FRAME STATION 827 BETWEEN S8 AND S9 AT RIVET ON CLIP. INSTALLED DOUBLER AND FILLER PER TYPICAL REPAIR 53-10-14. (M)