What was found
PIT - FOUND FLOORBEAM CORRODED 1 INCH BY 1 INCH AREA, STATION 344 BL0 BEAM. CORROSION LEVEL 2, FABRICATED SECTION, SPLICE ANGLES PER 53-10-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FLOORBEAM CORRODED 1 INCH BY 1 INCH AREA, STATION 344 BL0 BEAM. CORROSION LEVEL 2, FABRICATED SECTION, SPLICE ANGLES PER 53-10-51. (M)