What was found
PIT - FOUND FLAP TRACK CORRODED 3 AREAS, 1 INCH BY .5 INCH, ALL FLAP TRACK ROLLER CONTACT AREAS, NR 2 FLAP TRACK. REPLACED FLAP TRACK PER EO 5796X180. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FLAP TRACK CORRODED 3 AREAS, 1 INCH BY .5 INCH, ALL FLAP TRACK ROLLER CONTACT AREAS, NR 2 FLAP TRACK. REPLACED FLAP TRACK PER EO 5796X180. (M)