What was found
PIT - FOUND FLOOR SUPPORT CORRODED 2 INCHES BY 4 INCH AREA, FLOOR SUPPORT LBL 13 STATION 328-344.17. CORROSION LEVEL 2. CRM INSTALLED 113692 REF IPC 53-42-00-20, FASTENERS SRM 53-10-51 FIG 1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FLOOR SUPPORT CORRODED 2 INCHES BY 4 INCH AREA, FLOOR SUPPORT LBL 13 STATION 328-344.17. CORROSION LEVEL 2. CRM INSTALLED 113692 REF IPC 53-42-00-20, FASTENERS SRM 53-10-51 FIG 1. (M)