What was found
PIT - FOUND RIB AND SKIN WITH HEAVY CORROSION 4 INCHES LONG BY 1 INCH WIDE, RUDDER COUNTER BALANCE STRUCTURE, RUDDER STATION 121.64. LEVEL 2 CORROSION. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND RIB AND SKIN WITH HEAVY CORROSION 4 INCHES LONG BY 1 INCH WIDE, RUDDER COUNTER BALANCE STRUCTURE, RUDDER STATION 121.64. LEVEL 2 CORROSION. (M)