PIT - FOUND T-CAP FLOORBEAM CORRODED 2 INCHES LONG, FLOORBEAM STATION 328 AT LBL 28. CORROSION LEVEL 1. INSTALLED REPAIR DOUBLER AND NEW T-CAP PER SRM 53-10-51, PAGE 220. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND T-CAP FLOORBEAM CORRODED 2 INCHES LONG, FLOORBEAM STATION 328 AT LBL 28. CORROSION LEVEL 1. INSTALLED REPAIR DOUBLER AND NEW T-CAP PER SRM 53-10-51, PAGE 220. (M)