What was found
PIT - FOUND FRAME CORRODED 1 INCH BY 1 INCH CORRODED AREA, STATION 500B, BETWEEN STRINGERS 28L AND 28R. INSTALLED FABRICATED SHEAR TIE PER SRM 51-70-11. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FRAME CORRODED 1 INCH BY 1 INCH CORRODED AREA, STATION 500B, BETWEEN STRINGERS 28L AND 28R. INSTALLED FABRICATED SHEAR TIE PER SRM 51-70-11. (M)