What was found
PIT - FOUND SKIN CHAFED 1 INCH AREA, LEFT AIR CONDITION BAY STRUCTURE AT DOOR LATCH STATION BS 5. FABRICATED STRAP, TREATED, INSTALLED PER SRM 51-70-12 WITH EA 73950. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND SKIN CHAFED 1 INCH AREA, LEFT AIR CONDITION BAY STRUCTURE AT DOOR LATCH STATION BS 5. FABRICATED STRAP, TREATED, INSTALLED PER SRM 51-70-12 WITH EA 73950. (M)