What was found
PIT - FOUND FRAME CRACKED .25 INCHES IN LENGTH, STRINGER 9R, BS 867 AT PSU SUPPORT FITTING. CRACK CUT OUT, DOUBLER INSTALLED, FILLER ADDED PER TYPICAL REPAIR 53-10-14A. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.