What was found
PIT - FOUND ZEE ANGLE CORRODED TWO AREAS, FORWARD SERVICE DOOR ZEE ANGLE. REMOVED CORROSION PER SRM 51-10-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND ZEE ANGLE CORRODED TWO AREAS, FORWARD SERVICE DOOR ZEE ANGLE. REMOVED CORROSION PER SRM 51-10-02. (M)