What was found
PIT - FOUND FRAME CRACKED .25 INCH, STATION 767 BETWEEN S8L AND S9L AT PSU SUPPORT BRACKET. INSTALLED DOUBLER PER TYPICAL REPAIR 53-10-14A. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FRAME CRACKED .25 INCH, STATION 767 BETWEEN S8L AND S9L AT PSU SUPPORT BRACKET. INSTALLED DOUBLER PER TYPICAL REPAIR 53-10-14A. (M)